Servline — Engineering Solutions & Store
Pepperl+Fuchs K-System KCD2 isolated barrier
Pepperl+Fuchs logoPepperl+Fuchs

Pepperl+Fuchs K-System Isolated Barriers

Intrinsic safety isolators for hazardous-area signals — switch amplifiers, transmitter supplies, current drivers and temperature converters.

  • K-System
  • KCD2
  • KFD2
  • KFA6
  • Switch amplifiers, transmitter supplies, current drivers, temperature converters
  • Up to SIL 2 (IEC/EN 61508)
  • 12.5 mm KCD2 and 20 mm KFD2 housings
  • 24 V DC via Power Rail (KFA6: 230 V AC)
  • HART pass-through on transmitter and driver modules

Price on request — quoted per part number

Quotes within 24 hours on working days

  • Genuine products onlyNo copies, no substitutes without your approval.
  • Itemised quotationsClear prices, lead times and terms for every line.
  • Engineer-checkedWe confirm the right part for your application.
  • Delivery across PakistanDispatched to your plant, wherever it is.

About the Pepperl+Fuchs K-System Isolated Barriers

In chemical plants, refineries, paint shops and other hazardous areas, field instruments must be connected through intrinsic safety barriers that limit the energy reaching the Ex zone. Pepperl+Fuchs K-System isolators are among the most widely installed barriers in process plants worldwide, and a common spare in Pakistani process industries.

Each module does one job. Switch amplifiers (KCD2-SR, KFD2-SR2) pass NAMUR sensor or dry contact signals to relay outputs. SMART transmitter power supplies (KCD2-STC, KFD2-STC4) feed 2-wire 4–20 mA transmitters and pass HART. Current drivers (KCD2-SCD, KFD2-SCD2) drive valve positioners in the hazardous area, and temperature converters (KCD2-UT2, KFD2-UT2) accept thermocouples and RTDs. Most are rated up to SIL 2 and can be powered over the Power Rail.

We supply K-System modules as replacements and for new Ex loops. Send the type code from the module label and we match it; for new loops, send the instrument data and we select the barrier.

Range at a glance

Functions
Switch amplifier, SMART transmitter supply, SMART current driver, temperature converter
Supply
24 V DC (Power Rail); 230 V AC on KFA6
Safety integrity
Up to SIL 2
Housing width
12.5 mm (KCD2), 20 mm (KFD2/KFA6)
Signals
NAMUR/dry contact, 4–20 mA with HART, TC/RTD

Pepperl+Fuchs K-System Isolated Barriers part numbers

The codes our customers ask for most. Add the ones you need to your quote list — or send any other K-System Isolated Barriers variant and we check it for you.

Part numberDescriptionKey specQuote
KCD2-SR-Ex1.LBSwitch amplifier, 1 channel, NAMUR/dry contact input, relay output + fault relay1-ch · relay
KCD2-SR-Ex2Switch amplifier, 2 channels, NAMUR/dry contact input, relay outputs2-ch · relay
KFD2-SR2-Ex1.WSwitch amplifier, 1 channel, relay output, line fault detection1-ch · relay
KFD2-SR2-Ex2.WSwitch amplifier, 2 channels, relay outputs, line fault detection2-ch · relay
KFA6-SR2-Ex1.WSwitch amplifier, 1 channel, 230 V AC supply, relay output1-ch · 230 V AC
KFD2-SOT2-Ex1.LBIsolated switch amplifier, 1 channel, transistor output1-ch · transistor
KCD2-STC-Ex1SMART transmitter power supply, 1 channel, 4–20 mA / HART1-ch · 4–20 mA
KFD2-STC4-Ex1SMART transmitter power supply, 1 channel, 2/3-wire, 4–20 mA / HART1-ch · 4–20 mA
KCD2-SCD-Ex1SMART current driver, 1 channel, for valve positioners, HART1-ch · output
KFD2-SCD2-Ex1.LKSMART current driver, 1 channel, line fault detection, HART1-ch · output
KCD2-UT2-Ex1Universal temperature converter, TC/RTD input, 4–20 mA outputTC/RTD → 4–20 mA
KFD2-UT2-Ex1Universal temperature converter, TC/RTD input, 4–20 mA outputTC/RTD → 4–20 mA

Not sure of the part number?

Send a photo of the Pepperl+Fuchs part’s nameplate or label. Our engineers identify it and reply with the exact code and a quotation.

Pepperl+Fuchs K-System Isolated Barriers price in Pakistan

Pepperl+Fuchs K-System Isolated Barriers prices are quoted per part number. The final price depends on the exact code, the quantity and the exchange rate on the day, so we send an itemised quotation with prices, lead time and terms for every line.

To get a price, add part numbers from the table to your quote list, message us on WhatsApp, or send a photo of the nameplate. We deliver across Pakistan — Karachi, Lahore, Faisalabad, Islamabad and industrial areas in between.

Applications

Where the K-System Isolated Barriers is used

  • Chemical and petrochemical plants

    Transmitter, valve and switch loops in Zone 0/1/2 areas.

  • Paint and solvent areas

    Level switches and pressure transmitters near flammable liquids.

  • Replacement of failed barriers

    Like-for-like replacement to keep Ex loops certified.

Engineering support for the K-System Isolated Barriers

More from Pepperl+Fuchs

  • Pepperl+Fuchs M18 inductive sensor NBB8-18GM50-E2-V112 part numbers

    Cylindrical Inductive Sensors

    Pepperl+Fuchs cylindrical inductive sensors (NBB/NBN) in M8, M12, M18 and M30 housings: flush and non-flush, PNP and NPN, cable or M12 connector — rugged sensors for metal detection.

    • NBB
    • NBN
    • GM50
    • E2-V1
    View range
  • Pepperl+Fuchs VariKont L inductive sensor8 part numbers

    Rectangular Inductive Sensors

    Pepperl+Fuchs rectangular inductive sensors: compact F-series blocks and VariKont L2/U1 housings with sensing ranges up to 40 mm and a rotatable sensing head.

    • VariKont
    • NBN40-L2
    • NBN40-U1
    • F10
    View range
  • Pepperl+Fuchs M30 capacitive sensor8 part numbers

    Capacitive Sensors

    Pepperl+Fuchs capacitive sensors in M12, M18 and M30 housings and rectangular blocks, for detecting liquids, powders, granules and plastic or glass parts — often through a container wall.

    • CBB
    • CBN
    • CCB
    • CCN
    View range
  • Pepperl+Fuchs R100 series miniature photoelectric sensor7 part numbers

    R100 Series Photoelectric Sensors

    Pepperl+Fuchs R100 series miniature photoelectric sensors: background-suppression, diffuse, distance, retro-reflective and thru-beam types in one small housing with IO-Link.

    • R100
    • OBT
    • OBD
    • OBR
    View range
  • Pepperl+Fuchs M30 ultrasonic sensor10 part numbers

    Ultrasonic Sensors

    Pepperl+Fuchs ultrasonic sensors (UB and UC series) in M18 and M30 housings with switching or analog outputs and ranges up to 6 m — for tank level, distance and transparent objects.

    • UB
    • UC
    • 18GM
    • 30GM
    View range

FAQs

Frequently asked questions

Can I replace a K-System barrier with a different type?

Only if the replacement has equivalent safety parameters for the loop. The safe choice is the same type code — send it and we supply it.

What is the difference between KCD2 and KFD2 modules?

KCD2 modules are the newer 12.5 mm slim housings; KFD2 modules are 20 mm wide. Both families cover the same main functions.

What is the price of Pepperl+Fuchs K-System Isolated Barriers in Pakistan?

Prices depend on the exact part number, quantity and current exchange rate. Send us the codes you need and we reply with an itemised quotation. Quotes within 24 hours on working days.

My Pepperl+Fuchs part number is not in the table. Can you offer it?

The table shows the codes we are asked for most; we offer the other K-System Isolated Barriers variants too. Send the part number or a photo of the nameplate and we reply with a quotation.

Are these genuine Pepperl+Fuchs products?

Yes. We offer genuine Pepperl+Fuchs products only — no copies, and no substitutes without your approval.

Talk to an engineer

Request a Pepperl+Fuchs K-System Isolated Barriers quotation

Send the part numbers and quantities, a BOM or a nameplate photo. We check availability and reply with an itemised quotation.

Quotes within 24 hours on working days

Mon–Sat, 10:00 am – 8:00 pm

We’ll email a copy of your enquiry.

Nameplate photo, BOM or datasheet (optional)

Quotes within 24 hours on working days

Pepperl+Fuchs and related names, product images and logos are trademarks of their respective owner, used on this page for identification only. See our trademark notice.