Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC)

Armoured aluminium PVC cables for burial: single core to 630 mm², 3, 3½ and 4 core to 300 mm², rated per size.

  • Al/PVC/PVC/SWA/PVC
  • Al/PVC/PVC/AWA/PVC
  • IEC 60502-1
  • 0.6/1 kV
  • Steel wire armour for direct burial
  • 3, 3½ and 4 core 16 to 300 mm²
  • Single core to 630 mm² (aluminium armour)
  • Buried rating listed for every size
  • Diameter and weight per km

Price on request — quoted per part number

Quotes within 48 hours on working days

  • Genuine products onlyNo copies, no substitutes without your approval.
  • Itemised quotationsClear prices, lead times and terms for every line.
  • Engineer-checkedWe confirm the right part for your application.
  • Delivery across PakistanDispatched to your plant, wherever it is.

About the Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC)

Armoured aluminium cables are laid straight in the ground between buildings, to tube wells and pumps, along boundary walls and to outdoor equipment, and anywhere the cable could be crushed, cut or chewed by rodents. The construction reads from the inside out: aluminium conductor, PVC insulation, PVC bedding, galvanised steel wire armour and a PVC outer sheath.

Multicore cables use steel wire armour (SWA). Single cores use aluminium wire armour (AWA) instead, because steel around a single AC conductor heats up. Fast Cables makes three, 3½ and four core sizes from 16 to 300 mm² and single cores to 630 mm², to IEC 60502-1 for 0.6/1 kV. Each row gives the rating from Fast Cables' datasheet for one circuit buried directly at 20 °C ground temperature, with the approximate diameter and weight.

Depth, soil, grouping and voltage drop decide the final size. Send us the load, run length and route and we size and quote the cable.

Range at a glance

Conductor
Aluminium, class 1 or 2, circular or sector
Insulation / bedding / sheath
PVC / PVC / PVC
Armour
Galvanised steel wire (aluminium wire on single core)
Voltage
0.6/1 kV
Max. conductor temperature
70 °C (160 °C short circuit)
Ratings basis
Buried direct, 20 °C, soil 1.0 K·m/W

Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) part numbers

The codes our customers ask for most. Add the ones you need to your quote list — or send any other Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) variant and we check it for you.

Part numberDescriptionKey specQuote
1x16 mm² Al/PVC/PVC/AWA/PVCSingle-core 16 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 14.1 mm across, 276 kg/kmØ 14.1 mm
1x25 mm² Al/PVC/PVC/AWA/PVCSingle-core 25 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 16.6 mm across, 391 kg/kmØ 16.6 mm
1x35 mm² Al/PVC/PVC/AWA/PVCSingle-core 35 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 17.6 mm across, 450 kg/kmØ 17.6 mm
1x50 mm² Al/PVC/PVC/AWA/PVCSingle-core 50 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 152 A for two loaded cables (single-phase), 131 A for three (three-phase), buried directly at 20 °C ground temperature; about 19.3 mm across, 546 kg/km131 A 3-ph buried
1x70 mm² Al/PVC/PVC/AWA/PVCSingle-core 70 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 194 A for two loaded cables (single-phase), 168 A for three (three-phase), buried directly at 20 °C ground temperature; about 21.6 mm across, 657 kg/km168 A 3-ph buried
1x95 mm² Al/PVC/PVC/AWA/PVCSingle-core 95 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 234 A for two loaded cables (single-phase), 205 A for three (three-phase), buried directly at 20 °C ground temperature; about 23.9 mm across, 857 kg/km205 A 3-ph buried
1x120 mm² Al/PVC/PVC/AWA/PVCSingle-core 120 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 270 A for two loaded cables (single-phase), 238 A for three (three-phase), buried directly at 20 °C ground temperature; about 25.6 mm across, 983 kg/km238 A 3-ph buried
1x150 mm² Al/PVC/PVC/AWA/PVCSingle-core 150 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 310 A for two loaded cables (single-phase), 275 A for three (three-phase), buried directly at 20 °C ground temperature; about 27.5 mm across, 1,136 kg/km275 A 3-ph buried
1x185 mm² Al/PVC/PVC/AWA/PVCSingle-core 185 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 352 A for two loaded cables (single-phase), 315 A for three (three-phase), buried directly at 20 °C ground temperature; about 29.8 mm across, 1,337 kg/km315 A 3-ph buried
1x240 mm² Al/PVC/PVC/AWA/PVCSingle-core 240 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 413 A for two loaded cables (single-phase), 372 A for three (three-phase), buried directly at 20 °C ground temperature; about 33.6 mm across, 1,671 kg/km372 A 3-ph buried
1x300 mm² Al/PVC/PVC/AWA/PVCSingle-core 300 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 474 A for two loaded cables (single-phase), 430 A for three (three-phase), buried directly at 20 °C ground temperature; about 36.5 mm across, 2,023 kg/km430 A 3-ph buried
1x400 mm² Al/PVC/PVC/AWA/PVCSingle-core 400 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 543 A for two loaded cables (single-phase), 497 A for three (three-phase), buried directly at 20 °C ground temperature; about 40.4 mm across, 2,414 kg/km497 A 3-ph buried
1x500 mm² Al/PVC/PVC/AWA/PVCSingle-core 500 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 616 A for two loaded cables (single-phase), 568 A for three (three-phase), buried directly at 20 °C ground temperature; about 45.1 mm across, 2,909 kg/km568 A 3-ph buried
1x630 mm² Al/PVC/PVC/AWA/PVCSingle-core 630 mm² aluminium cable, PVC insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 692 A for two loaded cables (single-phase), 642 A for three (three-phase), buried directly at 20 °C ground temperature; about 50.6 mm across, 3,644 kg/km642 A 3-ph buried
3x16 mm² Al/PVC/PVC/SWA/PVCThree-core 16 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 61 A three-phase, buried directly at 20 °C ground temperature; about 24.1 mm across, 1,218 kg/km61 A buried
3x25 mm² Al/PVC/PVC/SWA/PVCThree-core 25 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 80 A three-phase, buried directly at 20 °C ground temperature; about 25.5 mm across, 1,378 kg/km80 A buried
3x35 mm² Al/PVC/PVC/SWA/PVCThree-core 35 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 99 A three-phase, buried directly at 20 °C ground temperature; about 26.5 mm across, 1,560 kg/km99 A buried
3x50 mm² Al/PVC/PVC/SWA/PVCThree-core 50 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 119 A three-phase, buried directly at 20 °C ground temperature; about 30.0 mm across, 1,887 kg/km119 A buried
3x70 mm² Al/PVC/PVC/SWA/PVCThree-core 70 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 151 A three-phase, buried directly at 20 °C ground temperature; about 33.7 mm across, 2,466 kg/km151 A buried
3x95 mm² Al/PVC/PVC/SWA/PVCThree-core 95 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 186 A three-phase, buried directly at 20 °C ground temperature; about 38.3 mm across, 3,006 kg/km186 A buried
3x120 mm² Al/PVC/PVC/SWA/PVCThree-core 120 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 216 A three-phase, buried directly at 20 °C ground temperature; about 41.0 mm across, 3,400 kg/km216 A buried
3x150 mm² Al/PVC/PVC/SWA/PVCThree-core 150 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 250 A three-phase, buried directly at 20 °C ground temperature; about 45.8 mm across, 4,408 kg/km250 A buried
3x185 mm² Al/PVC/PVC/SWA/PVCThree-core 185 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 287 A three-phase, buried directly at 20 °C ground temperature; about 50.3 mm across, 5,102 kg/km287 A buried
3x240 mm² Al/PVC/PVC/SWA/PVCThree-core 240 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 342 A three-phase, buried directly at 20 °C ground temperature; about 55.6 mm across, 6,130 kg/km342 A buried
3x300 mm² Al/PVC/PVC/SWA/PVCThree-core 300 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 399 A three-phase, buried directly at 20 °C ground temperature; about 60.9 mm across, 7,182 kg/km399 A buried
3x25+1x16 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 25 mm² cores plus a reduced 16 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 80 A three-phase, buried directly at 20 °C ground temperature; about 28.3 mm across, 1,561 kg/km80 A buried
3x35+1x16 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 35 mm² cores plus a reduced 16 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 99 A three-phase, buried directly at 20 °C ground temperature; about 31.0 mm across, 1,778 kg/km99 A buried
3x50+1x25 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 50 mm² cores plus a reduced 25 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 119 A three-phase, buried directly at 20 °C ground temperature; about 36.7 mm across, 2,429 kg/km119 A buried
3x70+1x35 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 70 mm² cores plus a reduced 35 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 151 A three-phase, buried directly at 20 °C ground temperature; about 40.0 mm across, 2,867 kg/km151 A buried
3x95+1x50 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 95 mm² cores plus a reduced 50 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 186 A three-phase, buried directly at 20 °C ground temperature; about 43.7 mm across, 3,563 kg/km186 A buried
3x120+1x70 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 120 mm² cores plus a reduced 70 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 216 A three-phase, buried directly at 20 °C ground temperature; about 50.0 mm across, 4,460 kg/km216 A buried
3x150+1x70 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 150 mm² cores plus a reduced 70 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 250 A three-phase, buried directly at 20 °C ground temperature; about 55.0 mm across, 5,189 kg/km250 A buried
3x185+1x95 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 185 mm² cores plus a reduced 95 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 287 A three-phase, buried directly at 20 °C ground temperature; about 60.0 mm across, 6,037 kg/km287 A buried
3x240+1x120 mm² Al/PVC/PVC/SWA/PVC3½-core aluminium cable (three 240 mm² cores plus a reduced 120 mm² neutral), PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 342 A three-phase, buried directly at 20 °C ground temperature; about 66.0 mm across, 7,236 kg/km342 A buried
4x16 mm² Al/PVC/PVC/SWA/PVCFour-core 16 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 61 A three-phase, buried directly at 20 °C ground temperature; about 26.0 mm across, 1,371 kg/km61 A buried
4x25 mm² Al/PVC/PVC/SWA/PVCFour-core 25 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 80 A three-phase, buried directly at 20 °C ground temperature; about 28.3 mm across, 1,635 kg/km80 A buried
4x35 mm² Al/PVC/PVC/SWA/PVCFour-core 35 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 99 A three-phase, buried directly at 20 °C ground temperature; about 31.0 mm across, 1,887 kg/km99 A buried
4x50 mm² Al/PVC/PVC/SWA/PVCFour-core 50 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 119 A three-phase, buried directly at 20 °C ground temperature; about 36.7 mm across, 2,573 kg/km119 A buried
4x70 mm² Al/PVC/PVC/SWA/PVCFour-core 70 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 151 A three-phase, buried directly at 20 °C ground temperature; about 40.0 mm across, 3,048 kg/km151 A buried
4x95 mm² Al/PVC/PVC/SWA/PVCFour-core 95 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 186 A three-phase, buried directly at 20 °C ground temperature; about 43.7 mm across, 4,093 kg/km186 A buried
4x120 mm² Al/PVC/PVC/SWA/PVCFour-core 120 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 216 A three-phase, buried directly at 20 °C ground temperature; about 50.0 mm across, 4,711 kg/km216 A buried
4x150 mm² Al/PVC/PVC/SWA/PVCFour-core 150 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 250 A three-phase, buried directly at 20 °C ground temperature; about 55.0 mm across, 5,498 kg/km250 A buried
4x185 mm² Al/PVC/PVC/SWA/PVCFour-core 185 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 287 A three-phase, buried directly at 20 °C ground temperature; about 60.0 mm across, 6,426 kg/km287 A buried
4x240 mm² Al/PVC/PVC/SWA/PVCFour-core 240 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 342 A three-phase, buried directly at 20 °C ground temperature; about 66.0 mm across, 7,773 kg/km342 A buried
4x300 mm² Al/PVC/PVC/SWA/PVCFour-core 300 mm² aluminium cable, PVC insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 399 A three-phase, buried directly at 20 °C ground temperature; about 73.0 mm across, 9,110 kg/km399 A buried

Not sure of the part number?

Send a photo of the Fast Cables part’s nameplate or label. Our engineers identify it and reply with the exact code and a quotation.

Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) price in Pakistan

Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) prices are quoted per part number. The final price depends on the exact code, the quantity and the exchange rate on the day, so we send an itemised quotation with prices, lead time and terms for every line.

To get a price, add part numbers from the table to your quote list, message us on WhatsApp, or send a photo of the nameplate. We deliver across Pakistan — Karachi, Lahore, Faisalabad, Islamabad and industrial areas in between.

Applications

Where the Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) is used

  • Underground feeders

    Between buildings across the site.

  • Tube wells and pumps

    Long buried runs to outlying loads.

  • Outdoor equipment

    Where cables can be damaged.

Engineering support for the Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC)

More from Fast Cables

  • Fast Cables building wires, red and black single-core9 part numbers

    House Wiring Cables (Building Wires)

    Fast Cables single-core Cu/PVC building wires for lighting, socket and appliance circuits: 1.0 to 6.0 mm² solid and stranded (450/750 V), plus the imperial 3/.029 and 7/.029 sizes, in 90 m coils and five colours.

    • Cu/PVC
    • 450/750 V
    • 3/.029
    • 7/.029
    View range
  • Fast Cables single-core low-voltage power cable10 part numbers

    Low-Voltage Power Cables (PVC & XLPE, Armoured)

    Fast Cables low-voltage power cables to IEC 60502-1: copper or aluminium, PVC or XLPE insulation, unarmoured or steel wire armoured (SWA), plus concentric and screened types — 1.5 to 800 mm², single and multicore.

    • IEC 60502-1
    • SWA
    • XLPE
    • 0.6/1 kV
    View range
  • Fast Cables H07V single-core wire7 part numbers

    Single-Core & Flexible Wiring Cables (H05V, H07V, H05VV-F)

    Fast Cables harmonised wiring cables: H05V-U/R/K (300/500 V) and H07V-U/R/K (450/750 V) single-core PVC wires to BS 6004, and H05VV-F flexible sheathed cords to BS EN 50525-2-11 for appliances and equipment.

    • H05V
    • H07V
    • H05VV-F
    • BS 6004
    View range
  • Fast Cables unarmoured aluminium power cable with stripped aluminium cores46 part numbers

    Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²)

    Fast Cables Al/PVC/PVC power cables to IEC 60502-1, 0.6/1 kV: single core 16–630 mm², three, 3½ and four core 16–300 mm², each listed with its current rating in air, outer diameter and weight.

    • Al/PVC/PVC
    • IEC 60502-1
    • 0.6/1 kV
    View range
  • Fast Cables unarmoured aluminium power cable with stripped aluminium cores46 part numbers

    Aluminium XLPE Power Cables (Al/XLPE/PVC, 16–630 mm²)

    Fast Cables Al/XLPE/PVC power cables to IEC 60502-1, 0.6/1 kV: single core 16–630 mm², three, 3½ and four core 16–300 mm², each listed with its current rating in air, outer diameter and weight.

    • Al/XLPE/PVC
    • IEC 60502-1
    • 0.6/1 kV
    • XLPE 90 °C
    View range
  • Fast Cables steel wire armoured power cable (copper version shown)45 part numbers

    Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC)

    Fast Cables Al/XLPE/PVC/SWA/PVC armoured power cables to IEC 60502-1, 0.6/1 kV: three, 3½ and four core 16–300 mm² with steel wire armour and single core 16–630 mm² with aluminium wire armour, listed with buried ratings, diameter and weight.

    • Al/XLPE/PVC/SWA/PVC
    • Al/XLPE/SWA/PVC
    • Al/XLPE/PVC/AWA/PVC
    • IEC 60502-1
    View range

FAQs

Frequently asked questions

What does 3x95+1x50 mean?

Three 95 mm² phase cores and one smaller 50 mm² neutral — the cable often called 3½ core. Use 4 equal cores where the neutral carries heavy or unbalanced load.

Why aluminium armour on single cores?

Steel is magnetic, so steel armour around a single AC conductor heats up from induced currents. Aluminium wire armour avoids that.

Do aluminium cables need special lugs?

Yes. Use aluminium or bimetallic (Al-Cu) lugs with contact compound, tightened to the right torque, so the joint does not overheat.

What is the price of Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) in Pakistan?

Prices depend on the exact part number, quantity and current exchange rate. Send us the codes you need and we reply with an itemised quotation. Quotes within 48 hours on working days.

My Fast Cables part number is not in the table. Can you offer it?

The table shows the codes we are asked for most; we offer the other Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) variants too. Send the part number or a photo of the nameplate and we reply with a quotation.

Are these genuine Fast Cables products?

Yes. We offer genuine Fast Cables products only — no copies, and no substitutes without your approval.

Talk to an engineer

Request a Fast Cables Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC) quotation

Send the part numbers and quantities, a BOM or a nameplate photo. We check availability and reply with an itemised quotation.

Quotes within 48 hours on working days

Mon–Sat, 10:00 am – 8:00 pm

We’ll email a copy of your enquiry.

Nameplate photo, BOM or datasheet (optional)

Quotes within 48 hours on working days

Fast Cables and related names, product images and logos are trademarks of their respective owner, used on this page for identification only. See our trademark notice.