Fast Cables steel wire armoured power cable (copper version shown)
Fast Cables logoFast Cables

Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC)

Armoured aluminium XLPE cables for burial: single core to 630 mm², 3, 3½ and 4 core to 300 mm², rated per size.

  • Al/XLPE/PVC/SWA/PVC
  • Al/XLPE/SWA/PVC
  • Al/XLPE/PVC/AWA/PVC
  • IEC 60502-1
  • XLPE insulation, 90 °C
  • Steel wire armour for direct burial
  • 3, 3½ and 4 core 16 to 300 mm²
  • Single core to 630 mm² (aluminium armour)
  • Buried rating listed for every size

Price on request — quoted per part number

Quotes within 48 hours on working days

  • Genuine products onlyNo copies, no substitutes without your approval.
  • Itemised quotationsClear prices, lead times and terms for every line.
  • Engineer-checkedWe confirm the right part for your application.
  • Delivery across PakistanDispatched to your plant, wherever it is.

About the Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC)

Al/XLPE/SWA is the usual choice for a buried main feeder in a factory: the transformer or grid supply to the main LT panel, and panel to panel across the site. XLPE insulation runs at 90 °C, so it carries noticeably more current than a PVC armoured cable of the same size, and the steel wire armour lets it go straight into the ground and protects it from damage and rodents.

Fast Cables builds it with an aluminium conductor, XLPE insulation, PVC bedding, galvanised steel wire armour and a PVC outer sheath, to IEC 60502-1 for 0.6/1 kV. Three, 3½ and four core cables run from 16 to 300 mm²; single cores to 630 mm² have aluminium wire armour. Each row gives the rating from Fast Cables' datasheet for one circuit buried directly at 20 °C ground temperature, with the approximate diameter and weight.

Depth, soil, grouping and voltage drop decide the final size. Send us the load, run length and route and we size and quote the cable.

Range at a glance

Conductor
Aluminium, class 2, circular or sector
Insulation / bedding / sheath
XLPE / PVC / PVC
Armour
Galvanised steel wire (aluminium wire on single core)
Voltage
0.6/1 kV
Max. conductor temperature
90 °C (250 °C short circuit)
Ratings basis
Buried direct, 20 °C, soil 1.0 K·m/W

Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) part numbers

The codes our customers ask for most. Add the ones you need to your quote list — or send any other Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) variant and we check it for you.

Part numberDescriptionKey specQuote
1x16 mm² Al/XLPE/PVC/AWA/PVCSingle-core 16 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 13.5 mm across, 251 kg/kmØ 13.5 mm
1x25 mm² Al/XLPE/PVC/AWA/PVCSingle-core 25 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 16.0 mm across, 362 kg/kmØ 16.0 mm
1x35 mm² Al/XLPE/PVC/AWA/PVCSingle-core 35 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — about 17.0 mm across, 412 kg/kmØ 17.0 mm
1x50 mm² Al/XLPE/PVC/AWA/PVCSingle-core 50 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 192 A for two loaded cables (single-phase), 162 A for three (three-phase), buried directly at 20 °C ground temperature; about 18.3 mm across, 482 kg/km162 A 3-ph buried
1x70 mm² Al/XLPE/PVC/AWA/PVCSingle-core 70 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 244 A for two loaded cables (single-phase), 207 A for three (three-phase), buried directly at 20 °C ground temperature; about 20.3 mm across, 599 kg/km207 A 3-ph buried
1x95 mm² Al/XLPE/PVC/AWA/PVCSingle-core 95 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 294 A for two loaded cables (single-phase), 252 A for three (three-phase), buried directly at 20 °C ground temperature; about 22.9 mm across, 762 kg/km252 A 3-ph buried
1x120 mm² Al/XLPE/PVC/AWA/PVCSingle-core 120 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 340 A for two loaded cables (single-phase), 292 A for three (three-phase), buried directly at 20 °C ground temperature; about 24.6 mm across, 887 kg/km292 A 3-ph buried
1x150 mm² Al/XLPE/PVC/AWA/PVCSingle-core 150 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 390 A for two loaded cables (single-phase), 337 A for three (three-phase), buried directly at 20 °C ground temperature; about 26.7 mm across, 1,037 kg/km337 A 3-ph buried
1x185 mm² Al/XLPE/PVC/AWA/PVCSingle-core 185 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 444 A for two loaded cables (single-phase), 391 A for three (three-phase), buried directly at 20 °C ground temperature; about 29.0 mm across, 1,221 kg/km391 A 3-ph buried
1x240 mm² Al/XLPE/PVC/AWA/PVCSingle-core 240 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 521 A for two loaded cables (single-phase), 465 A for three (three-phase), buried directly at 20 °C ground temperature; about 31.8 mm across, 1,475 kg/km465 A 3-ph buried
1x300 mm² Al/XLPE/PVC/AWA/PVCSingle-core 300 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 597 A for two loaded cables (single-phase), 540 A for three (three-phase), buried directly at 20 °C ground temperature; about 35.4 mm across, 1,830 kg/km540 A 3-ph buried
1x400 mm² Al/XLPE/PVC/AWA/PVCSingle-core 400 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 688 A for two loaded cables (single-phase), 625 A for three (three-phase), buried directly at 20 °C ground temperature; about 39.0 mm across, 2,188 kg/km625 A 3-ph buried
1x500 mm² Al/XLPE/PVC/AWA/PVCSingle-core 500 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 786 A for two loaded cables (single-phase), 714 A for three (three-phase), buried directly at 20 °C ground temperature; about 42.5 mm across, 2,628 kg/km714 A 3-ph buried
1x630 mm² Al/XLPE/PVC/AWA/PVCSingle-core 630 mm² aluminium cable, XLPE insulated, aluminium wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 880 A for two loaded cables (single-phase), 801 A for three (three-phase), buried directly at 20 °C ground temperature; about 49.6 mm across, 3,373 kg/km801 A 3-ph buried
3x16 mm² Al/XLPE/PVC/SWA/PVCThree-core 16 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 74 A three-phase, buried directly at 20 °C ground temperature; about 22.8 mm across, 1,086 kg/km74 A buried
3x25 mm² Al/XLPE/PVC/SWA/PVCThree-core 25 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 98 A three-phase, buried directly at 20 °C ground temperature; about 23.2 mm across, 1,226 kg/km98 A buried
3x35 mm² Al/XLPE/PVC/SWA/PVCThree-core 35 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 120 A three-phase, buried directly at 20 °C ground temperature; about 25.2 mm across, 1,405 kg/km120 A buried
3x50 mm² Al/XLPE/PVC/SWA/PVCThree-core 50 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 145 A three-phase, buried directly at 20 °C ground temperature; about 28.2 mm across, 1,666 kg/km145 A buried
3x70 mm² Al/XLPE/PVC/SWA/PVCThree-core 70 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 185 A three-phase, buried directly at 20 °C ground temperature; about 31.6 mm across, 1,977 kg/km185 A buried
3x95 mm² Al/XLPE/PVC/SWA/PVCThree-core 95 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 224 A three-phase, buried directly at 20 °C ground temperature; about 35.9 mm across, 2,647 kg/km224 A buried
3x120 mm² Al/XLPE/PVC/SWA/PVCThree-core 120 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 264 A three-phase, buried directly at 20 °C ground temperature; about 39.1 mm across, 3,072 kg/km264 A buried
3x150 mm² Al/XLPE/PVC/SWA/PVCThree-core 150 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 305 A three-phase, buried directly at 20 °C ground temperature; about 42.9 mm across, 3,540 kg/km305 A buried
3x185 mm² Al/XLPE/PVC/SWA/PVCThree-core 185 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 350 A three-phase, buried directly at 20 °C ground temperature; about 48.4 mm across, 4,622 kg/km350 A buried
3x240 mm² Al/XLPE/PVC/SWA/PVCThree-core 240 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 418 A three-phase, buried directly at 20 °C ground temperature; about 53.2 mm across, 5,445 kg/km418 A buried
3x300 mm² Al/XLPE/PVC/SWA/PVCThree-core 300 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 488 A three-phase, buried directly at 20 °C ground temperature; about 57.7 mm across, 6,425 kg/km488 A buried
3x25+1x16 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 25 mm² cores plus a reduced 16 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 98 A three-phase, buried directly at 20 °C ground temperature; about 26.8 mm across, 1,360 kg/km98 A buried
3x35+1x16 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 35 mm² cores plus a reduced 16 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 120 A three-phase, buried directly at 20 °C ground temperature; about 29.5 mm across, 1,580 kg/km120 A buried
3x50+1x25 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 50 mm² cores plus a reduced 25 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 145 A three-phase, buried directly at 20 °C ground temperature; about 34.3 mm across, 2,100 kg/km145 A buried
3x70+1x35 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 70 mm² cores plus a reduced 35 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 185 A three-phase, buried directly at 20 °C ground temperature; about 39.0 mm across, 2,564 kg/km185 A buried
3x95+1x50 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 95 mm² cores plus a reduced 50 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 224 A three-phase, buried directly at 20 °C ground temperature; about 42.9 mm across, 3,097 kg/km224 A buried
3x120+1x70 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 120 mm² cores plus a reduced 70 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 264 A three-phase, buried directly at 20 °C ground temperature; about 48.5 mm across, 4,046 kg/km264 A buried
3x150+1x70 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 150 mm² cores plus a reduced 70 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 305 A three-phase, buried directly at 20 °C ground temperature; about 53.4 mm across, 4,658 kg/km305 A buried
3x185+1x95 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 185 mm² cores plus a reduced 95 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 350 A three-phase, buried directly at 20 °C ground temperature; about 58.3 mm across, 5,494 kg/km350 A buried
3x240+1x120 mm² Al/XLPE/PVC/SWA/PVC3½-core aluminium cable (three 240 mm² cores plus a reduced 120 mm² neutral), XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 418 A three-phase, buried directly at 20 °C ground temperature; about 64.9 mm across, 6,512 kg/km418 A buried
4x16 mm² Al/XLPE/PVC/SWA/PVCFour-core 16 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 74 A three-phase, buried directly at 20 °C ground temperature; about 24.5 mm across, 1,224 kg/km74 A buried
4x25 mm² Al/XLPE/PVC/SWA/PVCFour-core 25 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 98 A three-phase, buried directly at 20 °C ground temperature; about 26.8 mm across, 1,444 kg/km98 A buried
4x35 mm² Al/XLPE/PVC/SWA/PVCFour-core 35 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 120 A three-phase, buried directly at 20 °C ground temperature; about 29.5 mm across, 1,696 kg/km120 A buried
4x50 mm² Al/XLPE/PVC/SWA/PVCFour-core 50 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 145 A three-phase, buried directly at 20 °C ground temperature; about 34.3 mm across, 2,270 kg/km145 A buried
4x70 mm² Al/XLPE/PVC/SWA/PVCFour-core 70 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 185 A three-phase, buried directly at 20 °C ground temperature; about 39.0 mm across, 2,737 kg/km185 A buried
4x95 mm² Al/XLPE/PVC/SWA/PVCFour-core 95 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 224 A three-phase, buried directly at 20 °C ground temperature; about 42.9 mm across, 3,292 kg/km224 A buried
4x120 mm² Al/XLPE/PVC/SWA/PVCFour-core 120 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 264 A three-phase, buried directly at 20 °C ground temperature; about 48.5 mm across, 4,250 kg/km264 A buried
4x150 mm² Al/XLPE/PVC/SWA/PVCFour-core 150 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 305 A three-phase, buried directly at 20 °C ground temperature; about 53.4 mm across, 5,005 kg/km305 A buried
4x185 mm² Al/XLPE/PVC/SWA/PVCFour-core 185 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 350 A three-phase, buried directly at 20 °C ground temperature; about 58.3 mm across, 5,829 kg/km350 A buried
4x240 mm² Al/XLPE/PVC/SWA/PVCFour-core 240 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 418 A three-phase, buried directly at 20 °C ground temperature; about 64.9 mm across, 6,991 kg/km418 A buried
4x300 mm² Al/XLPE/PVC/SWA/PVCFour-core 300 mm² aluminium cable, XLPE insulated, steel wire armoured, PVC sheathed, 0.6/1 kV, IEC 60502-1 — 488 A three-phase, buried directly at 20 °C ground temperature; about 70.6 mm across, 8,199 kg/km488 A buried

Not sure of the part number?

Send a photo of the Fast Cables part’s nameplate or label. Our engineers identify it and reply with the exact code and a quotation.

Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) price in Pakistan

Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) prices are quoted per part number. The final price depends on the exact code, the quantity and the exchange rate on the day, so we send an itemised quotation with prices, lead time and terms for every line.

To get a price, add part numbers from the table to your quote list, message us on WhatsApp, or send a photo of the nameplate. We deliver across Pakistan — Karachi, Lahore, Faisalabad, Islamabad and industrial areas in between.

Applications

Where the Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) is used

  • Transformer to LT panel

    Buried main feeders.

  • Site distribution

    Panel to panel between buildings.

  • Solar plant AC side

    Inverter to main panel runs.

Engineering support for the Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC)

More from Fast Cables

  • Fast Cables building wires, red and black single-core9 part numbers

    House Wiring Cables (Building Wires)

    Fast Cables single-core Cu/PVC building wires for lighting, socket and appliance circuits: 1.0 to 6.0 mm² solid and stranded (450/750 V), plus the imperial 3/.029 and 7/.029 sizes, in 90 m coils and five colours.

    • Cu/PVC
    • 450/750 V
    • 3/.029
    • 7/.029
    View range
  • Fast Cables single-core low-voltage power cable10 part numbers

    Low-Voltage Power Cables (PVC & XLPE, Armoured)

    Fast Cables low-voltage power cables to IEC 60502-1: copper or aluminium, PVC or XLPE insulation, unarmoured or steel wire armoured (SWA), plus concentric and screened types — 1.5 to 800 mm², single and multicore.

    • IEC 60502-1
    • SWA
    • XLPE
    • 0.6/1 kV
    View range
  • Fast Cables H07V single-core wire7 part numbers

    Single-Core & Flexible Wiring Cables (H05V, H07V, H05VV-F)

    Fast Cables harmonised wiring cables: H05V-U/R/K (300/500 V) and H07V-U/R/K (450/750 V) single-core PVC wires to BS 6004, and H05VV-F flexible sheathed cords to BS EN 50525-2-11 for appliances and equipment.

    • H05V
    • H07V
    • H05VV-F
    • BS 6004
    View range
  • Fast Cables unarmoured aluminium power cable with stripped aluminium cores46 part numbers

    Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²)

    Fast Cables Al/PVC/PVC power cables to IEC 60502-1, 0.6/1 kV: single core 16–630 mm², three, 3½ and four core 16–300 mm², each listed with its current rating in air, outer diameter and weight.

    • Al/PVC/PVC
    • IEC 60502-1
    • 0.6/1 kV
    View range
  • Fast Cables unarmoured aluminium power cable with stripped aluminium cores46 part numbers

    Aluminium XLPE Power Cables (Al/XLPE/PVC, 16–630 mm²)

    Fast Cables Al/XLPE/PVC power cables to IEC 60502-1, 0.6/1 kV: single core 16–630 mm², three, 3½ and four core 16–300 mm², each listed with its current rating in air, outer diameter and weight.

    • Al/XLPE/PVC
    • IEC 60502-1
    • 0.6/1 kV
    • XLPE 90 °C
    View range
  • Fast Cables steel wire armoured power cable (copper version shown)45 part numbers

    Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC)

    Fast Cables Al/PVC/PVC/SWA/PVC armoured power cables to IEC 60502-1, 0.6/1 kV: three, 3½ and four core 16–300 mm² with steel wire armour and single core 16–630 mm² with aluminium wire armour, listed with buried ratings, diameter and weight.

    • Al/PVC/PVC/SWA/PVC
    • Al/PVC/PVC/AWA/PVC
    • IEC 60502-1
    • 0.6/1 kV
    View range

FAQs

Frequently asked questions

What aluminium size replaces a copper cable?

Roughly 1.6 times the copper size for the same current — for example 95 mm² aluminium where 50–70 mm² copper would be used. Check the rating and voltage drop for your run; we can size it for you.

PVC or XLPE armoured?

XLPE carries about 20 % more current for the same size and handles short circuits better, so it often allows a smaller cable. PVC is cheaper for lighter loads.

Do aluminium cables need special lugs?

Yes. Use aluminium or bimetallic (Al-Cu) lugs with contact compound, tightened to the right torque, so the joint does not overheat.

What is the price of Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) in Pakistan?

Prices depend on the exact part number, quantity and current exchange rate. Send us the codes you need and we reply with an itemised quotation. Quotes within 48 hours on working days.

My Fast Cables part number is not in the table. Can you offer it?

The table shows the codes we are asked for most; we offer the other Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) variants too. Send the part number or a photo of the nameplate and we reply with a quotation.

Are these genuine Fast Cables products?

Yes. We offer genuine Fast Cables products only — no copies, and no substitutes without your approval.

Talk to an engineer

Request a Fast Cables Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC) quotation

Send the part numbers and quantities, a BOM or a nameplate photo. We check availability and reply with an itemised quotation.

Quotes within 48 hours on working days

Mon–Sat, 10:00 am – 8:00 pm

We’ll email a copy of your enquiry.

Nameplate photo, BOM or datasheet (optional)

Quotes within 48 hours on working days

Fast Cables and related names, product images and logos are trademarks of their respective owner, used on this page for identification only. See our trademark notice.