Fast Cables unarmoured aluminium power cable with stripped aluminium cores
Fast Cables logoFast Cables

Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²)

Unarmoured aluminium PVC cables, single core to 630 mm² and 3, 3½ and 4 core to 300 mm², with ratings per size.

  • Al/PVC/PVC
  • IEC 60502-1
  • 0.6/1 kV
  • Single core 16 to 630 mm²
  • 3, 3½ and 4 core 16 to 300 mm²
  • Current rating listed for every size
  • Diameter and weight per km
  • Lighter and cheaper than copper

Price on request — quoted per part number

Quotes within 48 hours on working days

  • Genuine products onlyNo copies, no substitutes without your approval.
  • Itemised quotationsClear prices, lead times and terms for every line.
  • Engineer-checkedWe confirm the right part for your application.
  • Delivery across PakistanDispatched to your plant, wherever it is.

About the Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²)

Al/PVC/PVC is the most economical power cable: an aluminium conductor, PVC insulation and a PVC outer sheath, with no armour. It suits feeders that run where they are already protected — on cable trays and ladders, in covered trenches, ducts and conduit, and inside panel rooms and buildings — for distribution boards, lighting and power sub-mains, motors and machines.

Fast Cables makes it to IEC 60502-1 for 0.6/1 kV with sector-shaped conductors on the larger multicore sizes. PVC runs at up to 70 °C. Each row below lists the current rating from Fast Cables' datasheet for cables in free air or on a perforated tray at 30 °C, with the approximate outer diameter for glands and trays and the weight per kilometre for transport.

Grouping, a hotter ambient and voltage drop over long runs all reduce the usable current, so treat these as a starting point. Send us the load, run length and installation method and we size and quote the cable.

Range at a glance

Conductor
Aluminium, class 1 or 2, circular or sector
Insulation / sheath
PVC / PVC
Voltage
0.6/1 kV
Max. conductor temperature
70 °C (160 °C short circuit)
Ratings basis
Free air or perforated tray, 30 °C
Flame retardant
IEC 60332-1-2

Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) part numbers

The codes our customers ask for most. Add the ones you need to your quote list — or send any other Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) variant and we check it for you.

Part numberDescriptionKey specQuote
1x16 mm² Al/PVC/PVCSingle-core 16 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — about 9.9 mm across, 142 kg/kmØ 9.9 mm
1x25 mm² Al/PVC/PVCSingle-core 25 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — about 11.5 mm across, 190 kg/kmØ 11.5 mm
1x35 mm² Al/PVC/PVCSingle-core 35 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — about 12.5 mm across, 226 kg/kmØ 12.5 mm
1x50 mm² Al/PVC/PVCSingle-core 50 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 149 A for two loaded cables (single-phase), 128 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 14.0 mm across, 293 kg/km128 A 3-ph in air
1x70 mm² Al/PVC/PVCSingle-core 70 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 192 A for two loaded cables (single-phase), 166 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 15.6 mm across, 378 kg/km166 A 3-ph in air
1x95 mm² Al/PVC/PVCSingle-core 95 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 235 A for two loaded cables (single-phase), 203 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 17.9 mm across, 494 kg/km203 A 3-ph in air
1x120 mm² Al/PVC/PVCSingle-core 120 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 273 A for two loaded cables (single-phase), 237 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 19.6 mm across, 570 kg/km237 A 3-ph in air
1x150 mm² Al/PVC/PVCSingle-core 150 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 316 A for two loaded cables (single-phase), 274 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 21.5 mm across, 713 kg/km274 A 3-ph in air
1x185 mm² Al/PVC/PVCSingle-core 185 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 363 A for two loaded cables (single-phase), 316 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 23.8 mm across, 874 kg/km316 A 3-ph in air
1x240 mm² Al/PVC/PVCSingle-core 240 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 430 A for two loaded cables (single-phase), 375 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 26.8 mm across, 1,111 kg/km375 A 3-ph in air
1x300 mm² Al/PVC/PVCSingle-core 300 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 497 A for two loaded cables (single-phase), 434 A for three (three-phase), in free air or on a perforated tray at 30 °C; about 29.8 mm across, 1,340 kg/km434 A 3-ph in air
1x400 mm² Al/PVC/PVCSingle-core 400 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 543 A for two loaded cables (single-phase), in free air or on a perforated tray at 30 °C; about 33.4 mm across, 1,700 kg/km543 A 1-ph in air
1x500 mm² Al/PVC/PVCSingle-core 500 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 629 A for two loaded cables (single-phase), in free air or on a perforated tray at 30 °C; about 39.4 mm across, 2,052 kg/km629 A 1-ph in air
1x630 mm² Al/PVC/PVCSingle-core 630 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 722 A for two loaded cables (single-phase), in free air or on a perforated tray at 30 °C; about 43.4 mm across, 2,534 kg/km722 A 1-ph in air
3x16 mm² Al/PVC/PVCThree-core 16 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 61 A three-phase, in free air or on a perforated tray at 30 °C; about 18.9 mm across, 461 kg/km61 A in air
3x25 mm² Al/PVC/PVCThree-core 25 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 78 A three-phase, in free air or on a perforated tray at 30 °C; about 19.3 mm across, 587 kg/km78 A in air
3x35 mm² Al/PVC/PVCThree-core 35 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 96 A three-phase, in free air or on a perforated tray at 30 °C; about 21.3 mm across, 706 kg/km96 A in air
3x50 mm² Al/PVC/PVCThree-core 50 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 117 A three-phase, in free air or on a perforated tray at 30 °C; about 24.6 mm across, 904 kg/km117 A in air
3x70 mm² Al/PVC/PVCThree-core 70 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 150 A three-phase, in free air or on a perforated tray at 30 °C; about 27.3 mm across, 1,151 kg/km150 A in air
3x95 mm² Al/PVC/PVCThree-core 95 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 183 A three-phase, in free air or on a perforated tray at 30 °C; about 31.5 mm across, 1,536 kg/km183 A in air
3x120 mm² Al/PVC/PVCThree-core 120 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 212 A three-phase, in free air or on a perforated tray at 30 °C; about 34.2 mm across, 1,835 kg/km212 A in air
3x150 mm² Al/PVC/PVCThree-core 150 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 245 A three-phase, in free air or on a perforated tray at 30 °C; about 38.0 mm across, 2,163 kg/km245 A in air
3x185 mm² Al/PVC/PVCThree-core 185 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 280 A three-phase, in free air or on a perforated tray at 30 °C; about 41.9 mm across, 2,719 kg/km280 A in air
3x240 mm² Al/PVC/PVCThree-core 240 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 330 A three-phase, in free air or on a perforated tray at 30 °C; about 47.2 mm across, 3,422 kg/km330 A in air
3x300 mm² Al/PVC/PVCThree-core 300 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 381 A three-phase, in free air or on a perforated tray at 30 °C; about 52.1 mm across, 4,117 kg/km381 A in air
3x25+1x16 mm² Al/PVC/PVC3½-core aluminium cable (three 25 mm² cores plus a reduced 16 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 78 A three-phase, in free air or on a perforated tray at 30 °C; about 23.1 mm across, 710 kg/km78 A in air
3x35+1x16 mm² Al/PVC/PVC3½-core aluminium cable (three 35 mm² cores plus a reduced 16 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 96 A three-phase, in free air or on a perforated tray at 30 °C; about 25.6 mm across, 835 kg/km96 A in air
3x50+1x25 mm² Al/PVC/PVC3½-core aluminium cable (three 50 mm² cores plus a reduced 25 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 117 A three-phase, in free air or on a perforated tray at 30 °C; about 29.9 mm across, 1,093 kg/km117 A in air
3x70+1x35 mm² Al/PVC/PVC3½-core aluminium cable (three 70 mm² cores plus a reduced 35 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 150 A three-phase, in free air or on a perforated tray at 30 °C; about 33.6 mm across, 1,382 kg/km150 A in air
3x95+1x50 mm² Al/PVC/PVC3½-core aluminium cable (three 95 mm² cores plus a reduced 50 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 183 A three-phase, in free air or on a perforated tray at 30 °C; about 38.8 mm across, 1,884 kg/km183 A in air
3x120+1x70 mm² Al/PVC/PVC3½-core aluminium cable (three 120 mm² cores plus a reduced 70 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 212 A three-phase, in free air or on a perforated tray at 30 °C; about 42.3 mm across, 2,213 kg/km212 A in air
3x150+1x70 mm² Al/PVC/PVC3½-core aluminium cable (three 150 mm² cores plus a reduced 70 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 245 A three-phase, in free air or on a perforated tray at 30 °C; about 47.2 mm across, 2,626 kg/km245 A in air
3x185+1x95 mm² Al/PVC/PVC3½-core aluminium cable (three 185 mm² cores plus a reduced 95 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 280 A three-phase, in free air or on a perforated tray at 30 °C; about 52.0 mm across, 3,240 kg/km280 A in air
3x240+1x120 mm² Al/PVC/PVC3½-core aluminium cable (three 240 mm² cores plus a reduced 120 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 330 A three-phase, in free air or on a perforated tray at 30 °C; about 58.8 mm across, 4,085 kg/km330 A in air
3x300+1x150 mm² Al/PVC/PVC3½-core aluminium cable (three 300 mm² cores plus a reduced 150 mm² neutral), PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 381 A three-phase, in free air or on a perforated tray at 30 °C; about 65.1 mm across, 5,012 kg/km381 A in air
4x16 mm² Al/PVC/PVCFour-core 16 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 61 A three-phase, in free air or on a perforated tray at 30 °C; about 20.8 mm across, 535 kg/km61 A in air
4x25 mm² Al/PVC/PVCFour-core 25 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 78 A three-phase, in free air or on a perforated tray at 30 °C; about 23.1 mm across, 725 kg/km78 A in air
4x35 mm² Al/PVC/PVCFour-core 35 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 96 A three-phase, in free air or on a perforated tray at 30 °C; about 25.6 mm across, 905 kg/km96 A in air
4x50 mm² Al/PVC/PVCFour-core 50 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 117 A three-phase, in free air or on a perforated tray at 30 °C; about 29.9 mm across, 1,150 kg/km117 A in air
4x70 mm² Al/PVC/PVCFour-core 70 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 150 A three-phase, in free air or on a perforated tray at 30 °C; about 33.6 mm across, 1,464 kg/km150 A in air
4x95 mm² Al/PVC/PVCFour-core 95 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 183 A three-phase, in free air or on a perforated tray at 30 °C; about 38.8 mm across, 2,020 kg/km183 A in air
4x120 mm² Al/PVC/PVCFour-core 120 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 212 A three-phase, in free air or on a perforated tray at 30 °C; about 42.3 mm across, 2,325 kg/km212 A in air
4x150 mm² Al/PVC/PVCFour-core 150 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 245 A three-phase, in free air or on a perforated tray at 30 °C; about 47.2 mm across, 2,868 kg/km245 A in air
4x185 mm² Al/PVC/PVCFour-core 185 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 280 A three-phase, in free air or on a perforated tray at 30 °C; about 52.0 mm across, 3,577 kg/km280 A in air
4x240 mm² Al/PVC/PVCFour-core 240 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 330 A three-phase, in free air or on a perforated tray at 30 °C; about 58.8 mm across, 4,436 kg/km330 A in air
4x300 mm² Al/PVC/PVCFour-core 300 mm² aluminium cable, PVC insulated and sheathed, unarmoured, 0.6/1 kV, IEC 60502-1 — 381 A three-phase, in free air or on a perforated tray at 30 °C; about 65.1 mm across, 5,488 kg/km381 A in air

Not sure of the part number?

Send a photo of the Fast Cables part’s nameplate or label. Our engineers identify it and reply with the exact code and a quotation.

Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) price in Pakistan

Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) prices are quoted per part number. The final price depends on the exact code, the quantity and the exchange rate on the day, so we send an itemised quotation with prices, lead time and terms for every line.

To get a price, add part numbers from the table to your quote list, message us on WhatsApp, or send a photo of the nameplate. We deliver across Pakistan — Karachi, Lahore, Faisalabad, Islamabad and industrial areas in between.

Applications

Where the Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) is used

  • Sub-main feeders

    Panel to distribution boards along trays.

  • Motor and machine supplies

    Protected runs inside the plant.

  • Buildings and sheds

    Economical runs in ducts and conduit.

Engineering support for the Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²)

More from Fast Cables

  • Fast Cables building wires, red and black single-core9 part numbers

    House Wiring Cables (Building Wires)

    Fast Cables single-core Cu/PVC building wires for lighting, socket and appliance circuits: 1.0 to 6.0 mm² solid and stranded (450/750 V), plus the imperial 3/.029 and 7/.029 sizes, in 90 m coils and five colours.

    • Cu/PVC
    • 450/750 V
    • 3/.029
    • 7/.029
    View range
  • Fast Cables single-core low-voltage power cable10 part numbers

    Low-Voltage Power Cables (PVC & XLPE, Armoured)

    Fast Cables low-voltage power cables to IEC 60502-1: copper or aluminium, PVC or XLPE insulation, unarmoured or steel wire armoured (SWA), plus concentric and screened types — 1.5 to 800 mm², single and multicore.

    • IEC 60502-1
    • SWA
    • XLPE
    • 0.6/1 kV
    View range
  • Fast Cables H07V single-core wire7 part numbers

    Single-Core & Flexible Wiring Cables (H05V, H07V, H05VV-F)

    Fast Cables harmonised wiring cables: H05V-U/R/K (300/500 V) and H07V-U/R/K (450/750 V) single-core PVC wires to BS 6004, and H05VV-F flexible sheathed cords to BS EN 50525-2-11 for appliances and equipment.

    • H05V
    • H07V
    • H05VV-F
    • BS 6004
    View range
  • Fast Cables unarmoured aluminium power cable with stripped aluminium cores46 part numbers

    Aluminium XLPE Power Cables (Al/XLPE/PVC, 16–630 mm²)

    Fast Cables Al/XLPE/PVC power cables to IEC 60502-1, 0.6/1 kV: single core 16–630 mm², three, 3½ and four core 16–300 mm², each listed with its current rating in air, outer diameter and weight.

    • Al/XLPE/PVC
    • IEC 60502-1
    • 0.6/1 kV
    • XLPE 90 °C
    View range
  • Fast Cables steel wire armoured power cable (copper version shown)45 part numbers

    Aluminium PVC Armoured Cables (Al/PVC/PVC/SWA/PVC)

    Fast Cables Al/PVC/PVC/SWA/PVC armoured power cables to IEC 60502-1, 0.6/1 kV: three, 3½ and four core 16–300 mm² with steel wire armour and single core 16–630 mm² with aluminium wire armour, listed with buried ratings, diameter and weight.

    • Al/PVC/PVC/SWA/PVC
    • Al/PVC/PVC/AWA/PVC
    • IEC 60502-1
    • 0.6/1 kV
    View range
  • Fast Cables steel wire armoured power cable (copper version shown)45 part numbers

    Aluminium XLPE Armoured Cables (Al/XLPE/PVC/SWA/PVC)

    Fast Cables Al/XLPE/PVC/SWA/PVC armoured power cables to IEC 60502-1, 0.6/1 kV: three, 3½ and four core 16–300 mm² with steel wire armour and single core 16–630 mm² with aluminium wire armour, listed with buried ratings, diameter and weight.

    • Al/XLPE/PVC/SWA/PVC
    • Al/XLPE/SWA/PVC
    • Al/XLPE/PVC/AWA/PVC
    • IEC 60502-1
    View range

FAQs

Frequently asked questions

What aluminium size replaces a copper cable?

Roughly 1.6 times the copper size for the same current — for example 95 mm² aluminium where 50–70 mm² copper would be used. Check the rating and voltage drop for your run; we can size it for you.

What does 3x95+1x50 mean?

Three 95 mm² phase cores and one smaller 50 mm² neutral — the cable often called 3½ core. Use 4 equal cores where the neutral carries heavy or unbalanced load.

Can Al/PVC/PVC be buried?

Only inside a duct or pipe. For direct burial use the armoured version (Al/PVC/PVC/SWA/PVC).

What is the price of Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) in Pakistan?

Prices depend on the exact part number, quantity and current exchange rate. Send us the codes you need and we reply with an itemised quotation. Quotes within 48 hours on working days.

My Fast Cables part number is not in the table. Can you offer it?

The table shows the codes we are asked for most; we offer the other Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) variants too. Send the part number or a photo of the nameplate and we reply with a quotation.

Are these genuine Fast Cables products?

Yes. We offer genuine Fast Cables products only — no copies, and no substitutes without your approval.

Talk to an engineer

Request a Fast Cables Aluminium PVC Power Cables (Al/PVC/PVC, 16–630 mm²) quotation

Send the part numbers and quantities, a BOM or a nameplate photo. We check availability and reply with an itemised quotation.

Quotes within 48 hours on working days

Mon–Sat, 10:00 am – 8:00 pm

We’ll email a copy of your enquiry.

Nameplate photo, BOM or datasheet (optional)

Quotes within 48 hours on working days

Fast Cables and related names, product images and logos are trademarks of their respective owner, used on this page for identification only. See our trademark notice.